Technical Data Sheets

Fluid Film  |  Liquid A  |  WRO-EP  |  Liquid AR  |  Gel BW  |  WRN |  Gel BEW

 

Fluid Film Aerosol & Non-Aerosol Pump

Product Data: #207
Effective January 2009

Fluid Film is a penetrant and lubricant also used for corrosion prevention. It is a non-toxic, long lasting, thixotropic liquid that has been used for over fifty years in the highly corrosive marine environment of ships and offshore drilling rigs. More recently they have been introduced and successfully utilized in the aerospace, aircraft and automobile industries as well as for home maintenance. Facilities where they are used include the following: government facilities, commercial fishing concerns, gas companies, agriculture, salt plants, municipal plants, power plants, manufacturing plants and pulp and paper mills.

Fluid Film is formulated from specially processed wool-wax, highly refined petroleum oils and selected agents to provide corrosion control, penetration, metal wetting and water displacement. The long lasting product contains no solvents, will not dry out and will penetrate to the base of all metals, providing corrosion protection from both natural and industrial atmospheres. Heavily corroded and/or frozen parts such as nuts, bolts, shafts, etc. that would normally be damaged during maintenance, can be salvaged by applying Fluid Film.

see applications

National Stock Number
11 3/4 OZ, 12/CTN Aerosol Spray   8030-01-387-1131
12 oz, 12/CTN Non-Aerosol   8030-01-381-6357
1 gal, 4/CTN Non-Aerosol   8030-01-386-3871
5 gal Pail Non-Aerosol   8030-01-387-1070
Environmentally Friendlier   AS (Less aerosol propellant) solvent free and non-toxic. NAS Solvent free and non-toxic. Container is reusable and recyclable. Read More about Fluid Film and the Environment.

Typical Properties
Unless designated otherwise, the following data refers to Fluid Film NAS or Fluid Film AS after the propellant has evaporated away following spray application.
Appearance:   Clear, straw colored liquid.
Viscosity:  
Brookfield
HBF, 70 ° F
#2 Spindle
at 2 RPM
2-4 reading
(3,200-6,400cps)
Flash Point, Bulk Liquid:
(ASTM-92)Cleveland Open Cup
  405°F minimum.
Non-Volatile:   89% minimum (3 hours @ 220°F).
V.O.C.:   Less than 1%
Specific Conductivity:  

Less than 10 -9 ohm/cm @ 1 mHz.

Specific Gravity:   0.875 - 0.885 (less propellant).
Effect on Rubber:
ASTM D-471 @ ± 158°F 70 hours
  None on neoprene, buna-n and most synthetics. Some swelling on natural.
Effect on Paint:   None on most painted surfaces.
Effect on Aluminum:   No pitting.
Extreme Pressure:
ASTM D-2782 Timken Method
  Fail load - 15 pounds.
Wear Prevention — Characteristics:

ASTM D-220 Four Ball Method

  40 Kg., 1200 RPM for 1 hour @ 167°F. Results: Scar diameter of 0.49mm.
Repaintability:   Contain no silicones. It is recommended that surfaces treated with Fluid Film® AS or NAS be hot water or steam detergent washed (120°F), whichever is most effective.
Corrosion Protection:
ASTM D-1735 Humidity Cabinet
  Passes 50 days.
ASTM D-1748:

Humidity Cabinet

  Passes 30 days. Corrosion Requirement (MIL-C-16173, Grade 3 -Soft Films), passes 5%. Salt Fog.
Water Replacement:   Displaces water from all metal surfaces (MIL-C-23411,Paragraph 3.6).
Toxicity:   Non-toxic, LD-50 greater than 3 grams per kilogram. Non-irritating skin response. Very slight irritation to the eyes. (Toxicity tests performed according to standard methods by an independent laboratory).
Warning:   AS: Extremely flammable. Contents under pressure. Do not puncture, incinerate or store above 120°F. Keep from open flame.

NAS: Combustible. Do not incinerate.
Spray Nozzle Cleaning:   Turn can upside down, point in a safe direction and spray until only propellant escapes. If spray button becomes clogged during use, pull it from the can and clean it with a fine wire or needle. Replace the button with a gentle twisting motion, keeping it pointed in a safe direction. Do not stick pins or other objects into nozzle tube.